适用线缆一览表 [ix Industrial™]

* This is a list of cables that have been evaluated by ix Industrial. Please confirm with the cable manufacturer for the mass production status of their cable.

Cat. 5e Cable

Cable supplier Product name Applicable connector Cable length (*2) Conductor Insulator Sheath (*3)
Straight Plug (*1) Inline
Jack
IX
30G*
IX
31G*
IX
32G*
IX
35G*
IX
40G
1m 5m Wire type Size Structure Outer dia.
[mm]
Outer dia.
[mm]
Material Outer dia.
[mm]
Color
AWG sq
Okano Cable R-OKTP-E5-P-AWG26×4P-SASB - - - Not evaluated Stranded 26 0.12 30/0.08 Ø0.50 Ø0.94 Lead-free,
Heat resistant PVC
Ø6.3 Light gray
Black
IX-26AWG×4P-SASB - - - Not evaluated Stranded 26 0.16 7/0.16 Ø0.48 Ø0.96 PVC Ø6.5 Gray
SS-FX-OKTP-E5-P-AWG30×4P-SASB(UL)※4 - - - Not evaluated Not evaluated Stranded 30 0.06 12/0.08 0.33 Ø0.66 Lead free heat resistant PVC Ø4.0 Light gray
SS-SR-OKTP-E5-P-AWG30×4P-SASB(UL) - - - Not evaluated Stranded 30 0.06 12/0.08 0.33 Ø0.63 Lead free heat resistant PVC Ø4.0 Light gray
NISSEI
ELECTRIC
G High Robot 920046 - - - Not evaluated Stranded 26 0.14 70/0.05 Ø0.54 Ø0.96 Oil-resistant PVC Ø6.8 Black
S4.0 for fixing - - - Not evaluated Not evaluated Stranded 30 0.05 7/0.102 0.306 Ø0.6 PVC Ø4.0 Black
Nippon
Seisen
Cable
4P NSEDT-PC-SB - - - Not evaluated Stranded 26 0.12 7/0.17 Ø0.51 Ø0.9 PVC Ø6.2 Blue
FRL3-NSEDT-PC-SB-MP4 N – L DB 568B BA(BK) - - - Not evaluated Stranded 25 0.18 7/0.18 Ø0.54 Ø0.89
~0.95
Flame-retardant PVC Ø6.6 Dark Blue
4P FRL3-SP5E-PC-SB (DB) - - - Not evaluated Not evaluated Stranded 28 0.09 7/0.13 φ0.39 Ø0.6 Flame-retardant PVC Ø5.1 Dark Blue
G-FRL3-SP5E-PC-SB (BK) - - - Not evaluated Not evaluated Stranded 28 0.08 40/0.05 φ0.40 Ø0.73 PVC Ø5.2 Black
PROTERIAL NETSTAR-C5E HQ SAB 4P D
(Standard number of Hitachi Metals [SP50-9681])
- - - Not evaluated Single 24 0.2 1/0.54 Ø0.54 Ø1.00 flame-retardant,
oil-resistant,
Lead-free PVC
Ø6.8 Orange
NETSTAR–C5E SAB 0.5×4P LBTK - - - Single 24 0.2 1/0.51 Ø0.51 Ø1.0 Lead-free PVC Ø6.5 Light Blue
Hirakawa
Hewtech
20276-ESV-4P×26AWG-RT-NON-PB(STP) - - - Not evaluated Stranded 26 0.15 30/0.08 Ø0.51 Ø0.96 Oil-resistant,
Lead-free PVC
Ø6.7 Black
21302-EALSV-4PX24AWG-NON-PB(STP) - - - Not evaluated Single 24 0.2 1/0.51 Ø0.51 Ø0.96 Non-migration,
Lead-free PVC
Ø6.5 Black
20379-ESV-4PX24AWG-7/0.2-NON-PB STP - - - Not evaluated Stranded 24 0.2 7/0.2 Ø0.60 Ø0.98 Lead-free PVC Ø6.4 Black
Oki Electric
Cable
OMNET-C5e HW-24AWG
(Former name: 0.5 4P DTI-C5e350(ALSV)VW1(S))
- - - Not evaluated Single 24 0.23 1/0.54 Ø0.54 Ø1.01 PVC Ø7.3 Gray
OMNET-C5e HW-26AWG Flex - - - Not evaluated Stranded 26 0.14 7/0.16 Ø0.48 Ø0.95 heat-resistant PVC Ø6.3 Black
Taiyo Cabletec
Corporation
TCAPTC-14003B FAFX-5E25SLAB(BK)
4P×25AWG
- - - Not evaluated Stranded 25 0.18 7/0.18 Ø0.54 Ø1.00 Flame-retardant Lead-free PVC Ø6.5 Black
TCAPTC-17004A FA-5E24SLAB/CM(GY)
4P×24AWG
- - - Not evaluated Single 24 0.22 1/0.53 Ø0.53 Ø1.03 Flame-retardant Lead-free PVC Ø6.9 Gray
FUJI
ELECTRIC
CABLE
HFS-TPCC 5 PATCH-FA 26AWG×4P - - - Not evaluated Stranded 26 0.15 30/0.08 Ø0.51 Ø0.91
~0.95
Oil-resistant PVC Ø6.1 Dark Blue
HFS-TPCC 5(S) PATCH-FA 28AWG X 4P - - - Not evaluated Stranded 28 0.08 30/0.06 0.38 ⌀0.62
~0.65
Oil-resistant PVC ⌀4.8 Dark Blue
HELUKABEL 82839 - - - Not evaluated Stranded 26 0.15 19/0.1 Ø0.501 Ø1.0 PUR Ø6.6
±0.2
Green
800653 - - - Not evaluated Single 22 0.32 1/0.64 Ø0.64 Ø1.5 PVC Ø6.5
±0.2
Green
800654 - - - Not evaluated Stranded 22 0.34 7/0.25 Ø0.75 Ø1.55 PVC Ø6.5
±0.2
Green
800655 - - - Not evaluated Stranded 22 0.34 7/0.25 Ø0.75 Ø1.55 PUR Ø6.5
±0.2
Green
Lapp Kabel ETHERLINE P Cat.5e 4×2×24/1 AWG - - - Not evaluated Single 24 0.25 1/0.51 Ø0.51 Ø1.04 PUR Ø6.1 Blue
ETHERLINE P FLEX Cat.5e 4×2×26/7 AWG - - - Not evaluated Stranded 26 0.141 7/0.16 Ø0.483 Ø0.95 PUR Ø6.1 Blue
Belden 7919A (Purchase area: Global, U.S.A.) - - - Not evaluated Single 24 0.2 1/0.51 Ø0.51 Ø1.02 PVC Ø6.7 Black
7958A (Purchase area: Global, U.S.A.) - - - Not evaluated Single 24 0.2 1/0.51 Ø0.51 Ø1.02 PVC Ø6.7 Black
74001E (Purchase area: Japan) - - - Not evaluated Single 24 0.21 1/0.52 Ø0.52 Ø1.1 PVC Ø6.8 Black
74001NH (Purchase area: Japan) - - - Not evaluated Single 24 0.21 1/0.52 Ø0.52 Ø1.1 LSZH Ø6.8 Blue
74002E (Purchase area: Japan) - - - Not evaluated Stranded 26 0.14 7/0.16 Ø0.48 Ø0.98 PVC Ø6.5 Black
74003PU (Purchase area: Japan) - - - Not evaluated Stranded 26 0.15 19/0.1 Ø0.5 Ø1.0 PUR Ø6.65 Black

Cat. 6A Cable

Cable supplier Product name Applicable connector Cable length (*2) Conductor Insulator Sheath (*3)
Straight Plug (*1) Inline
Jack
IX
30G*
IX
31G*
IX
32G*
IX
35G*
IX
40G
1m 5m Wire type Size Structure Outer dia.
[mm]
Outer dia.
[mm]
Material Outer dia.
[mm]
Color
AWG sq
Nippon
Seisen
Cable
4P NSGDT6-PC-10G-SB - - - Not evaluated Stranded 26 0.12 7/0.17 Ø0.51 Ø0.90 PVC Ø6.3 Light blue
4P FRL3-SPG6-PC-10G-SB (DB) - - - Not evaluated Not evaluated Stranded 28 0.09 7/0.13 φ0.39 Ø0.6 PVC Ø5.8 Dark Blue
PROTERIAL NETSTAR-C6A SASB 25AWGX4P LF
(Standard number of Hitachi Metals [SP50-43113])
- - - Not evaluated Stranded 25 0.18 7/0.18 Ø0.54 Ø1.10 Lead-free PVC Ø6.8 Black
Quabbin 4PR. SF/UTP HIGH FLEX INDUSTRIAL
ETHERNET/IP PATCH CORD -- CATEGORY 6/6a
- - - Not evaluated Stranded 26 0.14 7/0.16 Ø0.48 Ø0.91 Thermoplastic elastomer Ø7.0 Teal
Taiyo Cabletec
Corporation
TCAPTC-17005 FAFX-6A26SLAB(BK)
4P×26AWG
- - - Not evaluated Stranded 26 0.16 7/0.17 Ø0.46 Ø0.84 Flame-retardant Lead-free PVC Ø6.5 Black
TCAPTC-20001 FAMV-6A26SLAB/CM(BK) 4P×26AWG - - - Not evaluated Stranded 26 0.12 30/0.08 Φ0.47 Φ0.91 Flame-retardant Lead-free PVC Φ6.4 Black
Dyden
Corporation
RMH-CAT6AⅡ - - - Not evaluated Stranded 26 0.15 7/
11/
0.05
Ø0.58 Ø1.02 Thin-wall abrasion-resistant PVC Ø7.1 Black
FUJI
ELECTRIC
CABLE
HFS-TPCC 6A PATCH-FA 26AWG×4P - - - Not evaluated Stranded 26 0.15 30/0.08 Ø0.51 Ø0.88
~Ø0.95
Oil-resistant PVC Ø6.8 Dark Blue
HFS-TPCC 6A(S) PATCH-FA 28AWG X 4P - - - Not evaluated Stranded 28 0.08 30/0.06 0.38 ⌀0.62
~0.65
Oil-resistant PVC ⌀5.0 Dark Blue
Hirakawa
Hewtech
20379-ESV-4P×26AWG-NON-Pb SF/UTP 6A - - - Not evaluated Stranded 26 0.15 30/0.08 Ø0.51 Ø0.93 Lead-free PVC Ø6.8 Black
Okano Cable IX-10G 26AWG×4P-SASB - - - Not evaluated Stranded 26 0.16 7/0.16 Ø0.48 Ø0.96 Lead-free PVC Ø6.5 Gray
Harting 09 45 600 05 - - - Not evaluated Please contact the cable manufacturer directly
09 45 600 06 - - - Not evaluated Please contact the cable manufacturer directly

Cat. 7 Cable (Since ix Industrial's performance is Cat. 6A, compatibility evaluation is conducted at Cat. 6A.)

Cable supplier Product name Applicable connector Cable length (*2) Conductor Insulator Sheath (*3)
Straight Plug (*1) Inline
Jack
IX
30G*
IX
31G*
IX
32G*
IX
35G*
IX
40G
1m 5m Wire type Size Structure Outer dia.
[mm]
Outer dia.
[mm]
Material Outer dia.
[mm]
Color
AWG sq
LEONI L45467-J415-C246 - - - Not evaluated Stranded 26 0.12 7/0.16 Ø0.48 Ø1.0 Thermoplastic copolymer (FRNC: Flame-retardant Low-smoke) Ø7.1±0.2 Black
HELUKABEL 802184 - - - Not evaluated Stranded 26 0.14 7/0.16 Ø0.48 Ø1.04 PUR Ø6.4±0.3 Green

Other cables *Other than Ethernet cables

Cable supplier Product name Applicable connector Conductor Insulator Pairs数 Sheath (*3)
Straight Plug (*1) Inline
Jack
IX
30G*
IX
31G*
IX
32G*
IX
35G*
IX
40G
Wire type Size Structure Outer dia.
[mm]
Outer dia.
[mm]
Pairs Material Outer dia.
[mm]
Color
AWG sq
MISUMI SS300CMSB - - - Not evaluated Stranded 28 0.08 7/0.127 Ø0.38 Ø0.90 5 Heat resistant PVC Ø6.5±0.3 Black
ST30RSB - - - Not evaluated Stranded 24 0.2 44/0.08 Ø0.61 Ø0.91 5 Thin-wall abrasion-resistant PVC Ø6.4 Black
*1
IX30G*: IDC plug. Applicable cable size is 26-28 AWG.
IX31G*: IDC plug. Applicable cable size is 24-25 AWG.
IX32G*: IDC plug. Applicable cable size is 22 AWG.
IX35G*: IDC plug. Applicable cable size is 30 AWG.
IX40G: Soldering plug. Applicable cable size is 22-28 AWG.
*2
Hirose carried out compliance test for RL and NEXT characteristics with cable assembly lengths of 1m and 5m to simulate actual use. All tested connectors are straight plug type A. Evaluation results are measured with a double ended IX plug harness, not characteristics of cable itself. Evaluation results are confirmed, not guaranteed values.
*3
If the sheath outer diameter does not meet our recommended value, we process it with heat shrink tubing, etc., and conduct evaluation.
*4
The harness used for evaluation does not follow HRS recommended cable processing method. Please contact the cable manufacturer for the processing method.